PIP


prolactin induced protein


Gene Context Sentence


Table 2. Analysis of context sentence of PIP gene in 9 abstracts.

PMID Gene Context Sentence
32252845 This extreme measure never seen before during peace time was the result of adapting not only the French Pandemic Influenza Plan (PIP) being applied to the national context but also real-time clinical, epidemiological and scientific information about the evolution of COVID-19 infection in the country.
32687919 At a static lung compliance of 50 mL/cm H2O and an airway resistance of 6 cm H2O/L/s, ventilated at a PIP and PEEP of 16 and 5 cm H2O, respectively, tidal volumes of approximately 540 mL were achieved. […] At a static lung compliance of 20 mL/cm H2O and an airway resistance of 6 cm H2O/L/s, ventilated at a PIP and PEEP of 38 and 15 cm H2O, respectively, tidal volumes of approximately 495 mL were achieved.
32835141 Experimental results after testing on an artificial lung for peak inspiratory pressure (PIP), respiratory rate (RR), positive end-expiratory pressure (PEEP), tidal volume, proximal pressure, and lung pressure demonstrate repeatability and accuracy exceeding human capabilities in BVM-based manual ventilation.
32842276 The Pandemic Influenza Preparedness Framework for the sharing of influenza viruses and access to vaccines and other benefits (the ‘PIP Framework’ or ‘Framework’) is an international arrangement adopted by the World Health Organization in May 2011 to improve global pandemic influenza preparedness and response. […] Since the transmission route and transmission capacity of COVID-19 are similar to that of influenza A (H1N1) in 2009, which conforms to the basic elements of “human pandemic”, and the epidemic scale has exceeded that of influenza A (H1N1), it is probable to incorporate COVID-19 epidemic response into PIPF, and at the same time to verify and improve PIPF in practice. […] It is recommended that WHO, other international organizations and relevant countries make full use of the PIPF system to respond to the epidemic and better coordinate national actions at the global level.
33015423 ATMO-Vent is capable of adjusting the Fraction of Inspiratory Oxygen (FiO2) levels, Tidal Volume (TV), frequency of breaths, Inspiratory/Expiratory ratio (I/E), Peak Inspiratory Pressure (PIP) and Positive End-Expiratory Pressure (PEEP).
33194539 The ventilator is limited to a fixed ratio between PIP and PEEP.
33378363 In response to the need for mechanical ventilators, designed and tested an emergency ventilator (EV) that can control a patient’s peak inspiratory pressure (PIP) and breathing rate, while keeping a positive end expiratory pressure (PEEP).
33439605 After engaging the ventilator, PEEP and peak inspiratory pressure(PIP) were measured by the reference manometer and the anesthesia machine display simultaneously. […] Utilizing non-parametric Bland-Altman analysis, the reference and machine manometer measurements of PIP demonstrated median differences of -0.40 cmH2O (95%LOA: -1.00,0.55) for the Dräger Apollo, -0.40 cmH2O (95%LOA: -1.10, 0.41) for the Dräger Perseus, and 1.70 cmH2O (95%LOA: 0.80,3.00) for the GE Avance CS2.
33500377 He developed subcutaneous emphysema (SE) and pneumomediastinum on day 5 of mechanical ventilation at ventilatory settings of positive end-expiratory pressure (PEEP) ≤15 cmH₂O, plateau pressure (Pplat) ≤25 cmH₂O and pulmonary inspiratory pressure (PIP) ≤30 cmH₂O. […] She developed extensive SE with pneumomediastinum and pneumothorax while on mechanical ventilation settings PEEP 13 cmH₂O and PIP 28 cmH₂O, Pplat 18 cmH₂O, and FiO2 90%.